It is desired to filter a cell broth at a rate of 3000 liters/h on a rotary vacuum filter at a vacuum pressure of 70kPa. The cycle time for the drum will be 60 s and the cake formation time (filtering time) will be 20 s. The broth to be filtered has a viscosity of 2.0 cP and a cake solids (dry basis) per volume of filtrate of 10 g/liter. From laboratory test, the specific cake resistance has been determined to be 9 x 1010 cm/g. Determine the area of the filter that is required.